1 May 2010 15:49
Re: SEISAN Updates
luisa On Wed, 28 Apr 2010, rsncol@... wrote: > Hi, > > We are having troubles with updating our seisan from older versions to the > 8.1.3 and 8.2.1 (for linux). > The first one is that when we update the database with the program UPDATE > v8.1.3, it changes the location of the events that where updated form eev. > We decided to test the update from 7.1.2 version with the eev from 8.2.1 > version and it works well, it doesn't change the location of the events. > Now, we are having troubles with the location and updating database, because > we are using the S-P differences in some stations, so we set the weight for > the P phase input record to 9 and locate the events. The events are located > and well updated from eev, but when we update the database (with the update > v7.1.2), they turn to high values the RMS factor, and change the hypocenter. > We changed again the update version to the 8.1.3 and update from eev and then > the database, we found that again the location changes but the RMS factor > remains low. So, we prefer to not use the S-P differences, but it make us > think that there is something wrong with our SEISAN, or with all this > versions we use. > How can we solve it? > we jsut discovered that since 2005, the update program does not useprogram does no uance weight, so that migh explain why you get different results. this will be fixed soon, we actually plan to release a new version of seisan within 3 weeks.(Continue reading)