Giuseppe NICASTRO | 2 Dec 2002 16:13
Picon

RDC coefficiets

Dear

I am a new user of xplor-nih.1.2.1. I am working on a globular protein and
I would like to define its global fold using only RDC restraints starting
from a model builded by homology modeling.  I have a problem about the
values of the dipolar coupling coefficients in sani part. Do they refer to
Da and Dr (the axial and rhombic components, respectively, of the
molecular alignment tensor) or to Da and R (axial and rhombicity (defined
as Dr/Da) ?

 Thank you in advance for your time

             with best regards,

				Beppe

___________________________________________________________

Giuseppe Nicastro, PhD
C.I.M. Centro Interfacolta' Misure
Universita' degli Studi di Parma
Viale delle Scienze
43100-Parma, ITALY
phone: (++39)-521-905129
e-mail: beppe <at> unipr.it

___________________________________________________________

Darek Kedra | 5 Dec 2002 23:14

xplor-nih_2.0.5/bin/xplor reports wrong version

Dear Sirs,

this is probably a minor bug, but after running: 
xplor-nih_2.0.5/bin/xplor

I've got:

XPLOR-NIH version 2.0.4

Hope it helps.

Darek Kedra
--

-- 
Darek Kedra MD PhD 
The Burnham Institute                   ph: +858-646-3100 ext.3915
Information Systems Department          fax: +858-646-3171
10901 North Torrey Pines Rd          e-mail: darked <at> burnham.org
La Jolla, CA 92037, USA 

Sarah Williams | 16 Dec 2002 08:00

NMR.CIT.NIH.GOV

Hi

I visited NMR.CIT.NIH.GOV, and noticed that you're not listed on some search engines! I think we can offer you a service which can help you increase traffic and the number of visitors to your website.

I would like to introduce you to TrafficMagnet.com. We offer a unique technology that will submit your website to over 300,000 search engines and directories every month.

 

You'll be surprised by the low cost, and by how effective this website promotion method can be.

To find out more about TrafficMagnet and the cost for submitting your website to over 300,000 search engines and directories, visit www.TrafficMagnet.com.

I would love to hear from you.


Best Regards,

Sarah Williams
Sales and Marketing
E-mail: sarah_williams <at> trafficmagnet.com
http://www.TrafficMagnet.com

This email was sent to xplor-nih <at> nmr.cit.nih.gov. We apologize if this email has reached you in error.
We honor all removal requests. Please click here to be removed from our mailing list.

nobuyuki_sama | 22 Dec 2002 01:15
Picon

Generalized Born module in Xplor-NIH

Hi,

I tried to use GB by xplor-nih version 2.0.5.

However, xplor-nih cannot read the NONBONDED parameter accurately. 
There are extra 2 column real numbers in NONBond parameter for 
Generalized Born calculation.

The xplor-nih will terminate the simulation during the reading the 
parameter set.

Is it Bug?

Nobuyuki Ota