mritorto | 1 Mar 2012 01:49

Re: printer monitoring

hey i got snmp polling by how do I have openms do an snmp get to determine
whats going on with printers

is that defined in data collections.xml file?

do I need to do anything in collections.xmls file?

right now i only see standard resource graphs soI know snmp is working now

marc

--
View this message in context: http://opennms.530661.n2.nabble.com/printer-monitoring-tp7327682p7331228.html
Sent from the OpenNMS - discuss mailing list archive at Nabble.com.

------------------------------------------------------------------------------
Virtualization & Cloud Management Using Capacity Planning
Cloud computing makes use of virtualization - but cloud computing 
also focuses on allowing computing to be delivered as a service.
http://www.accelacomm.com/jaw/sfnl/114/51521223/
_______________________________________________
Please read the OpenNMS Mailing List FAQ:
http://www.opennms.org/index.php/Mailing_List_FAQ

opennms-discuss mailing list

To *unsubscribe* or change your subscription options, see the bottom of this page:
https://lists.sourceforge.net/lists/listinfo/opennms-discuss

(Continue reading)

Klaus Steden | 1 Mar 2012 03:05
Favicon

Re: printer monitoring


What you get back depends a great deal on the printer manufacture and
model.

Check the sysObjectID of the printer itself, and then see if you can find
it in datacollection-config.xml.

If it's not there in some way shape or form, you'll have to put something
together to help OpenNMS identify printer-specific data points.

cheers,
Klaus

On 2/29/12 4:49 PM, "mritorto" <mritorto <at> sumitomotrustusa.com> etched on
stone tablets:

>hey i got snmp polling by how do I have openms do an snmp get to determine
>whats going on with printers
>
>
>is that defined in data collections.xml file?
>
>do I need to do anything in collections.xmls file?
>
>right now i only see standard resource graphs soI know snmp is working now
>
>marc
>
>--
>View this message in context:
(Continue reading)

mritorto | 1 Mar 2012 05:34

Re: printer monitoring

is the datacollection the only file I need to work with

--
View this message in context: http://opennms.530661.n2.nabble.com/printer-monitoring-tp7327682p7331607.html
Sent from the OpenNMS - discuss mailing list archive at Nabble.com.

------------------------------------------------------------------------------
Virtualization & Cloud Management Using Capacity Planning
Cloud computing makes use of virtualization - but cloud computing 
also focuses on allowing computing to be delivered as a service.
http://www.accelacomm.com/jaw/sfnl/114/51521223/
_______________________________________________
Please read the OpenNMS Mailing List FAQ:
http://www.opennms.org/index.php/Mailing_List_FAQ

opennms-discuss mailing list

To *unsubscribe* or change your subscription options, see the bottom of this page:
https://lists.sourceforge.net/lists/listinfo/opennms-discuss

Klaus Steden | 1 Mar 2012 05:48
Favicon

Re: printer monitoring


If your device shows up and is collecting MIB-II SNMP data, for instance,
you should only have to make changes to datacollection-config.xml

I've found with some of my devices that I needed to tweak OID and OID mask
settings.

hth,
Klaus

On 2/29/12 8:34 PM, "mritorto" <mritorto <at> sumitomotrustusa.com> etched on
stone tablets:

>is the datacollection the only file I need to work with
>
>--
>View this message in context:
>http://opennms.530661.n2.nabble.com/printer-monitoring-tp7327682p7331607.h
>tml
>Sent from the OpenNMS - discuss mailing list archive at Nabble.com.
>
>--------------------------------------------------------------------------
>----
>Virtualization & Cloud Management Using Capacity Planning
>Cloud computing makes use of virtualization - but cloud computing
>also focuses on allowing computing to be delivered as a service.
>http://www.accelacomm.com/jaw/sfnl/114/51521223/
>_______________________________________________
>Please read the OpenNMS Mailing List FAQ:
>http://www.opennms.org/index.php/Mailing_List_FAQ
(Continue reading)

PENZ Robert | 1 Mar 2012 10:49
Picon
Favicon

Re: 1.10.0 and Dashboard exception

Hi!

Noone has an idea? Is this a common/known problem?

Mit freundlichen Grüßen
Robert Penz

-----Ursprüngliche Nachricht-----
Von: PENZ Robert [mailto:ROBERT.PENZ <at> TIROL.GV.AT] 
Gesendet: Dienstag, 28. Februar 2012 17:26
An: 'opennms-discuss <at> lists.sourceforge.net'
Betreff: [opennms-discuss] 1.10.0 and Dashboard exception

Hi!

I've upgraded to 1.10.0 and everthing seems to work but the dashboard. I get following 

com.google.gwt.user.client.rpc.IncompatibleRemoteServiceException: This application is out of
date, please click the refresh button on your browser. ( Expecting version 6 from server, got 7. )

Can someone tell me what I did wrong during the update and how I can fix it. Thx!

Mit freundlichen Grüßen
Robert Penz

----------------------------------------------------
Dipl. Inf. Robert Penz
DVT-Daten-Verarbeitung-Tirol GmbH
Adamgasse 22, 6020 Innsbruck
Tel: +43 512 508 3334 / Fax: +43 512 508 3355
(Continue reading)

Patrick Tuite | 1 Mar 2012 12:03
Picon

Problem with DataCollection interface naming on LevelOne Switch

Hi

I see from the DataCollection Howto wiki that:

/For each interface on the node that is being used for data collection,
a subdirectory will exist consisting of the interface description
(ifDescr) and the MAC address. The MAC address was added because on some
switches, multiple ports will have the same ifDescr. There have been
tales of devices where the interfaces had both the same ifDescr and MAC
address, and at the moment no solution exists for that case. So, if on
node 18 there was an interface described as "eth0", its RRD directory
would be |/var/opennms/rrd/snmp/18/eth0-[MAC Addr.]|. Into that
directory would go all interface specific RRD files such as
ifInOctets.rrd and ifOutOctets.rrd/

The LevelOne switches have different ifDesc for each interface, but the
same ifName.

Only one rrd folder is being created with [ifName]-[MAC-Addr] with
pretty strange output. Anyway to force it to use ifDesc, or part of instead?

IF-MIB::ifDescr.1 = STRING: Port1: 10Base-T/100Base-TX/1000Base-T
IF-MIB::ifDescr.2 = STRING: Port2: 10Base-T/100Base-TX/1000Base-T
IF-MIB::ifDescr.3 = STRING: Port3: 10Base-T/100Base-TX/1000Base-T
IF-MIB::ifDescr.4 = STRING: Port4: 10Base-T/100Base-TX/1000Base-T
IF-MIB::ifDescr.5 = STRING: Port5: 10Base-T/100Base-TX/1000Base-T
IF-MIB::ifDescr.6 = STRING: Port6: 10Base-T/100Base-TX/1000Base-T
IF-MIB::ifDescr.7 = STRING: Port7: Dual Media for 1000Base-T/1000Base-SX/LX
IF-MIB::ifDescr.8 = STRING: Port8: Dual Media for 1000Base-T/1000Base-SX/LX

(Continue reading)

Bc. Lukáš Bajus | 1 Mar 2012 16:36
Picon

final thesis

Hi,

I'm student of Technical University in Kosice, Slovakia. I am using
Opennms in my final thesis. I want to ask if I can monitor certain
indicators from specific web page. Such as: current number of visitors at
page, size of the web page at the moment, response time of the page. And
set some Threshold to generate event if some conditions are met. For
example: if response time is higher than 400 ms, and number of visitors is
more than 1000 and size is over 20kB. Is that possible with Opennms?

Thanks!

------------------------------------------------------------------------------
Virtualization & Cloud Management Using Capacity Planning
Cloud computing makes use of virtualization - but cloud computing 
also focuses on allowing computing to be delivered as a service.
http://www.accelacomm.com/jaw/sfnl/114/51521223/
_______________________________________________
Please read the OpenNMS Mailing List FAQ:
http://www.opennms.org/index.php/Mailing_List_FAQ

opennms-discuss mailing list

To *unsubscribe* or change your subscription options, see the bottom of this page:
https://lists.sourceforge.net/lists/listinfo/opennms-discuss

Heiko Katzler | 1 Mar 2012 16:50
Favicon

Config for low threshold on a router interface


Hello List

i want to configure a low threshold.

For example. On a specified router i want monitor an interface. If the Bits
per second went under 200 kbit/s opennms should sent me a notification. If
the bits per second went above 500 kbit/s the threshold should be rearmed
and i should get a resolved notification.

What i have to do to configure the threshold? Below you can find my config:

<threshold description="Monitoring Bits per second" type="low"
            ds-type="if" value="200.0" rearm="500.0" trigger="1"
            triggeredUEI="GLS/custom/bitsunder200"
            rearmedUEI="GLS/custom/bitsover500" filterOperator="or"
ds-name="ifHCInOctets"/>

Is this Correct? If i have defined a correct threshold i can setup my
notification.

Best regards

Heiko

___________________________________________________________________________________________________________________

GLS IT Services GmbH
Sitz: Neuenstein, Amtsgericht Bad Hersfeld HRB 388, Geschäftsführer: Rüdiger Schmahl
___________________________________________________________________________________________________________________
(Continue reading)

Bc. Lukáš Bajus | 1 Mar 2012 17:33
Picon

monitoring web page


Hi,

I'm student of Technical University in Kosice, Slovakia. I am using
Opennms in my final thesis. I want to ask if I can monitor certain
indicators from specific web page. Such as: current number of visitors at
page, size of the web page at the moment, response time of the page. And
set some Threshold to generate event if some conditions are met. For
example: if response time is higher than 400 ms, and number of visitors is
more than 1000 and size is over 20kB. Is that possible with Opennms?

Thanks!

------------------------------------------------------------------------------
Virtualization & Cloud Management Using Capacity Planning
Cloud computing makes use of virtualization - but cloud computing 
also focuses on allowing computing to be delivered as a service.
http://www.accelacomm.com/jaw/sfnl/114/51521223/
_______________________________________________
Please read the OpenNMS Mailing List FAQ:
http://www.opennms.org/index.php/Mailing_List_FAQ

opennms-discuss mailing list

To *unsubscribe* or change your subscription options, see the bottom of this page:
https://lists.sourceforge.net/lists/listinfo/opennms-discuss

mritorto | 1 Mar 2012 17:48

snmp-graph.properties file is causing a http 503 error

guys

I am the following changes to my snmp-graph properties file to graph jvm and
now my I can't access opennms 

I get a http 503 error 

can any one help me

see settings below

top of file

mssql, mssql.log, mssql.data, mssql.perf
jvm.heap, jvm.nonheap,jvm.threads, jvm.uptime, jvm.gc, jvm.mempool \

lower section 

###
## JVM by marc j ritorto
###

report.jvm.heap.name=JVM Heap Memory
report.jvm.heap.columns=jvmHeapUsed, jvmHeapCommitted, jvmHeapMax
report.jvm.heap.type=nodeSnmp
report.jvm.heap.command=--title="JVM Heap Memory" \
 DEF:used={rrd1}:jvmHeapUsed:AVERAGE \
 DEF:comm={rrd2}:jvmHeapCommitted:AVERAGE \
 DEF:max={rrd3}:jvmHeapMax:AVERAGE \
 AREA:used#0000ff:"Used     " \
(Continue reading)