Optek SNMP | 3 Apr 2006 15:15

CiscoCSS plugin for genDevConfig


A genDevConfig plugin for Cisco Content Services Switch series is available to download from http://www.optekconsulting.com/snmp/

The plugin supports the original ArrowPoint MIB and the more recent Cisco MIB.

The Cisco CSS uses a variable length OID as table indicies where the index is actually the owner / content /
service name represented as ASCII character codes. This makes it quite painstaking to build a CSS
configuration by hand. This plugin automates the cricket targets generation.

Forewarning; there are bugs in the arrowpoint MIB implementation that mean devices with large/complex
CSS configurations will exhibit excessive CPU load when polled via SNMP under certain circumstance. So
use this plugin in accordance with the included disclaimer (entirely at your own risk) and upgrade to a bug
free CSS firmware version before doing so.

Enjoy!

Optek SNMP
snmp <at> optekconsulting.com

-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language
that extends applications into web and mobile media. Attend the live webcast
and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642
Naveen Baldeo | 10 Apr 2006 03:49
Picon
Favicon

Cricket Monitor Thresholds

Hi,

 

I am having a problem. I have setup threshold monitoring on a router in the default section as below.

 

target --default--

   monitor-thresholds = "ifOutOctets : value : n : 8750000 : MAIL : %mail-pgm% : me\\\ <at> xxxxx.com.au"

 

This works where 8750000 bytes/s (70 Mbits/s), that is 70% of the total 100 M Link.

 

The problem I am having is that, this router has many interfaces of different speed (1Gbits, 100 Mbits & 10 Mbits).

I can not put the above command on each interface with different values, this will take to much time and there are 1000s of links / interface.

This there a way to put the % value (i.e. 70%) instead of the value as above.

 

   monitor-thresholds = "ifOutOctets : value : n : 70 pct : MAIL : %mail-pgm% : me\\\ <at> xxxxx.com.au"   

 

I have tried the above command, it give an alarm on 70 bytes/s and not 70% of 100M (i.e. 8750000 bytes).

 

 

Regards,

 

Naveen Baldeo

David Koski | 11 Apr 2006 07:04
Picon

FW: Bytes - port traffic

Ok, I’m a little confused so maybe someone can explain this better to me.  For port traffic, cricket by default specifies bytes:

bytes

Default value: none

If this is set to true, then the conversion to SI units will use powers of 2 instead of powers of 10. For instance, if a router is reporting that it's moving 1048576 bits per second through a particular interface, and "bytes" is set to 1 (or "true") then the value will be reported in the HTML summary as 1 Mbit/sec. Without the bytes tag, the value would be reported at 1.04 Mbit/sec, which is slightly misleading. When measuring very large numbers of bytes, the difference can be significant (4.9% in the case of Mega sized measurements, 7.3% in the case of Giga sized measurements). This is the major cause of discrepancies between Cricket and some commercial tools, so make sure it's set appropriately.

The numbers on the vertical axis of a graph are scaled by powers of 2 if the bytes tag is set to true for any of the datasources on the graph.

 

Which leads to an rrd base value of 1024.

However, isn’t bits per second calculated on 1000 and not 1024?

Per rrdtool:

[-b|--base value]

If you are graphing memory (and NOT network traffic) this switch should be set to 1024 so that one Kb is 1024 byte. For traffic measurement, 1 kb/s is 1000 b/s.

Should the sample Defaults NOT specify bytes = true for ifInOctets and the alike for the rrd base value doesn’t specify 1024 but 1000 per the grapher.cgi code?

Wouldn’t this be bytes per second and not bits per second (Converting to 1 Megabyte not 1 megabit per second, hence the label of bits per second misleading?”

graph   ifInOctets

    color       =   dark-green

    draw-as     =   AREA

    legend      =   "Average bits in"

    y-axis      =   "bits per second"

    units       =   "bits/sec"

    scale       =   8,*

    bytes       =   true

As I said, I’m just a smiggen confused.  Myabe someone could help me out.

               David

!DSPAM:443b307b90124239313241!

Michael Bunk | 11 Apr 2006 11:01
Favicon

Re: Cricket Monitor Thresholds

Hi Naveen,

On Monday 10 April 2006 03:49, Naveen Baldeo wrote:
...
> target --default--
>
>    monitor-thresholds = "ifOutOctets : value : n : 8750000 : MAIL :
> %mail-pgm% : me\\\ <at> xxxxx.com.au"
>
> This works where 8750000 bytes/s (70 Mbits/s), that is 70% of the total
> 100 M Link.
>
> The problem I am having is that, this router has many interfaces of
> different speed (1Gbits, 100 Mbits & 10 Mbits).
>
> I can not put the above command on each interface with different values,
> this will take to much time and there are 1000s of links / interface.
>
> This there a way to put the % value (i.e. 70%) instead of the value as
> above.
>
>
>
>    monitor-thresholds = "ifOutOctets : value : n : 70 pct : MAIL :
> %mail-pgm% : me\\\ <at> xxxxx.com.au"
>
>
>
> I have tried the above command, it give an alarm on 70 bytes/s and not
> 70% of 100M (i.e. 8750000 bytes).

Like I already wrote on 2006-03-22 10:44 to Kuder, David A. , you can't use 
"value" thresholds for that. Try quotient or relation together with what you 
read via SNMP for IF-MIB::ifSpeed.

Michael

-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language
that extends applications into web and mobile media. Attend the live webcast
and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642
Geoffrey Schwartzreich | 11 Apr 2006 22:58

GenRtrConfig 1.5.50 and PIX v7.0

I'm not sure if this specific question has been asked before...a search
turned up very little.

I'm having an issue with genRtrConfig 1_5_50 and a pair of PIX 515E's that I
need to monitor for CPU/Temp/Load. I have played around with the targets
file a bit, and it is trying to get this data, but the following is the
result:

>Received SNMP response with error code noSuchName. OID:
>1.3.6.1.4.1.9.9.109.1.1.1.1.4.0

So, I do a snmpwalk -v 1 ip_addr_of_pix 1.3.6.1.4.1.9.9.109.1.1.1.1.4

And I get:

> SNMPv2-SMI::enterprises.9.9.109.1.1.1.1.4.1 = Gauge32: 4

So, it looks like the OID in the Defaults file is wrong for the PIX v7, but
if I put that OID into the Defaults file I get:

>Received SNMP response with error code noSuchName. OID:
>1.3.6.1.4.1.9.9.109.1.1.1.1.4.1.0

Thoughts?

Geoff

-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language
that extends applications into web and mobile media. Attend the live webcast
and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642
Naveen Baldeo | 12 Apr 2006 02:55
Picon
Favicon

monitor-thresholds

Hi,

I am having a problem. I have setup threshold monitoring on a router in the default section as below.

 

target --default--

monitor-thresholds =

   "ifOutOctets : quotient : 20 pct : : %rrd-max-octets% : MAIL : %mail-pgm% : naveen.baldeo\\\ <at> optus.com.au,

    ifOutOctets : quotient : 30 pct : : %rrd-max-octets% : MAIL : %mail-pgm% : naveen.baldeo\\\ <at> optus.com.au,

    ifInOctets : quotient : 20 pct : : %rrd-max-octets% : MAIL : %mail-pgm% : naveen.baldeo\\\ <at> optus.com.au,

    ifInOctets : quotient : 30 pct : : %rrd-max-octets% : MAIL : %mail-pgm% : naveen.baldeo\\\ <at> optus.com.au"

 

This does not do anything. What am I doing wrong.

 

From the attached page.

    ifInOctets : quotient : >80pct : : %rrd-max-octets% : SNMP,

* The second generates an SNMP trap whenever the utilized bandwidth, ifInOctets, exceeds 80% of it's maximum capacity, %rrd-max-octets%. %rrd-max-octets% is a cricket variable that is replaced at runtime with it's real value.

 

If this command can generate an SNMP trap, then change the SNMP to MAIL, should generate an email.

 

 

Regards,

 

Naveen Baldeo

Understanding and Utilizing Cricket Monitor Thresholds

Although designed as a real-time data collection and trending tool, real-time alerts (or alarms) are a natural extended functionality for Cricket. Unfortunately, because they are not a part of the core design, the alert mechanisms in Cricket are not as cleanly implemented or efficient as they could be. If your interest is purely in a tool to generate real-time alerts, then Cricket is probably not the best choice. But if you already utilize Cricket for data collection and real-time trend analysis and you have the additional need for some light real-time alerting mechanism, then Cricket can meet your needs.

In Cricket, the alert mechanism is called a monitor threshold. Monitor thresholds are set (or enabled) for specific data sources through the monitor-thresholds target dictionary tag. After the data collection pass, Cricket processes each monitor threshold by retrieving the most recent value of a data source from the RRD file and applying some criteria specific to the monitor threshold type. This criteria generates either a pass or fail condition. Depending on the setting of the persistent-alarms tag for the target, Cricket executes a specified action.

Note that the most recent value of a data source from the RRD file will not necessarily agree with the most recent value fetched from by the collector because RRDtool interpolates.  For those familiar with RRD tool internals, the "most recent value" is retreived from the first RRA in the file with a consolidation function of AVERAGE. The order of RRAs in the file is specified by the rra tag in the targetType dictionary.

Note that a monitor threshold configured for a multi-instance (aka vector instances) target will be checked and an action possibly executed for each instance. Monitor thresholds are not supported for multi-targets (as multi-targets are purely a construct of the Cricket grapher).

Syntax

monitor-thresholds = "<monitor-threshold> [, <monitor-threshold> ...]"

<data source> := a data source defined for the target; Case sensitive.

<monitor type> := One of the six supported types: exact, value, relation, hunt, quotient, or failures. Case insensitive.

<monitor type args> := a colon-delimited list of arguments specific to each monitor type. Case sensitive

<ACTION> := One of six supported actions: SNMP, MAIL, EXEC, FUNC, META or FILE. Case insensitive.

<action args> := a colon-delimited list of arguments specific to each action. Case sensitive in most cases.

<SPAN> := Spanning keyword: SPAN. Case insensitive.

<span-length> := Number of time spans a thresholds should fail before triggering an action. Number.

Format Examples

Please consider these as examples on using monitor thresholds, not best practices.

target --default--     mail-pgm = /usr/bin/mailx     trap-address = 127.0.0.1     persistent-alarms = true target network-link-1     monitor-thresholds =     "ifInOctets : value : n : 250000 : SNMP,     ifInOctets : quotient : >80pct : : %rrd-max-octets% : SNMP,      ifInOctets : relation : <10 pct : : : 300 : MAIL :  %mail-pgm% : me\\\ <at> mydomain.com,      ifInErrors : quotient : 0.1 pct : : ifInUcastPackets : SNMP" target pop-2     persistent-alarms = false     monitor-thresholds = "users : hunt : 40 : pop-1 : users : FILE : /var/log/cricket-alerts" target router-chassis     persistent-alarms = false     monitor-thresholds = "cpu1min : value : n : 60 : META : router-cpu : yellow,      cpu1min : value : n : 90 : META : router-cpu : red : SPAN : 3,      mem5minUsed : quotient : >60pct : : processorRam: META"

Note: Make sure to include spaces/tabs leading each line related to a target as above. Or else Cricket will not process the line.

Explaining the Examples

target network-link-1     monitor-thresholds =     "ifInOctets : value : n : 250000 : SNMP,     ifInOctets : quotient : >80pct : : %rrd-max-octets% : SNMP,      ifInOctets : relation : <10 pct : : : 300 : MAIL :  %mail-pgm% : me\\\ <at> mydomain.com,      ifInErrors : quotient : 0.1 pct : : ifInUcastPackets : SNMP"

The first target, network-link-1, has three monitor thresholds.

  • The first generates an SNMP trap whenever the utilized bandwidth, ifInOctets, exceeds 2 Mbps (2000000bits /8 = 250000 octets). It is important to note that all entries defined in the --default-- section will be inhereted by each target. In this case, persistent-alarms = true, has a direct impact when the action will be executed.
  • The second generates an SNMP trap whenever the utilized bandwidth, ifInOctets, exceeds 80% of it's maximum capacity, %rrd-max-octets%. %rrd-max-octets% is a cricket variable that is replaced at runtime with it's real value.
  • The third monitor threshold, checks to see if the current bandwidth, ifInOctets, has a value that is within 10% of the value recorded for the last interval (300 seconds ago; assuming an rrd-poll-interval of 300 seconds). It computes abs(ifInOctets_now - ifInOctets_then)/ifInOctets then and compares this with 10% (0.1). If traffic levels have increased more than 10% over the interval, it invokes mailx to send a mail message to me <at> mydomain.com (note the escaped backslash and escaped ' <at> '). This action will also be executed everytime the threshold is crossed due to the inherited persistent-alarms.
  • The fourth monitor threshold checks to see if input errors, ifInErrors, exceed 0.1% of input packets, ifInUcastPackets. If errors exceed this threshold, Cricket generates an SNMP trap.
target pop-2     persistent-alarms = false     monitor-thresholds = "users : hunt : 40 : pop-1 : users : FILE : /var/log/cricket-alerts"

The second target, pop-2, has a single monitor threshold.

  • Cricket will append an entry to the file /var/log/cricket-alerts when a non-zero number of users, popUsers, are on pop-2 yet pop-1 has not reached 40 users. Once pop-1 reaches 40 users, or  pop-2 returns to a zero user count, the entry will be cleared from the file. A target can always redefine a variable that was set in the --default-- section or inhereted from lower in the config tree. In this case persistent-alarms are reset to the default value of false. Hence, the FILE action will be executed to set the alarm when the alarm condition is first detected and once to clear the alarm when the alarm condition is cleared.
target router-chassis     persistent-alarms = false     monitor-thresholds = "cpu1min : value : n : 60 : META : router-cpu : yellow,      cpu1min : value : n : 90 : META : router-cpu : red : SPAN : 3,      mem5minUsed : quotient : >60pct : : processorRam: META"

The third target, router-chassis, has a three monitor thresholds.

  • The first two make use of the value monitor type to establish thresholds on cpu usage. More than one identical monitor type can be applied against the same datasource. In both cases, the META action is called with different arguments.
  • In the second value monitor, the keyword SPAN indicates there is an additional condition where the monitor threshold will only trigger an alarm when three consecutive monitor threshold tests fail. At the first threshold test pass, the alarm will be cleared.
  • The last monitor type will calculate mem5minUsed datasource divided by the processorRAM datasource and if the percentage is greater than 60% it will trigger a META action. Note that no additional arguments have been added to the META action, this is by design, read the Actions section for details on how to use this and other actions.

Persistent Alarms

By default, the target tag persistent-alarms is set to false. With this setting, the first time a monitor threshold criteria fails, the action is executed.  Specifically, the Alarm() subroutine in the Monitor.pm module is invoked; the action and its arguments are passed as arguments. If the criteria continues to fail (at subsequent data collection passes), the action is not executed again. After one or more failures, the first time the monitor threshold criteria passes, the action is executed. In this case, the Clear() subroutine in the Monitor.pm module is invoked, with appropriate action and action arguments.  Thus the default behavior is like a switch that toggles states when the result of the monitor threshold criteria changes.

If the target tag persistent-alarms is true, the action is executed (the Alarm subroutine is invoked) every time the monitor threshold criteria fails. An action (and Clear subroutine) is still executed once the first time the criteria passes after a string of failures. With persistent-alarms set to true, monitor threshold behavior is like a bell. It keeps ringing until the problem stops.

Monitor Types

The monitor type determines the criteria used to check a monitor threshold.

exact :

These monitors are the simplest to use and configure, and allow you to monitor a datasource for an exact match. This is useful in cases where an enumerated (or boolean) SNMP object instruments a condition where a transition to a specific state requires attention. For example, a datasource might return either true(1) or false(2), depending on whether or not a power supply has failed. The exact monitor expects one argument; the value on which the monitor will trigger. For example, monitor-thresholds = "dsPowerFail:exact:1" would cause Cricket to send a trap when the last value of the "dsPowerFail" datasource in the RRD file for this target is 1.

dsPowerFail : exact : 1 : <ACTION> : ... dsTempAlarm : exact : 1 : <ACTION> : ...

value :

The next simplest monitor type, value monitor thresholds take two arguments, a minimum and maximum value. If the data source strays outside of this interval, the monitor threshold criteria fails. To omit the minimum or maximum value, use the character "n".

temperature : value : 30 : 90 : <ACTION> : ... ifInOctets : value : n : 250000 : <ACTION> : ...

relation :

Relation monitor thresholds are very flexible. A relation monitor considers the difference between two data sources (possibly from different targets), or alternatively, the difference between two temporally distinct values for the same data source. The first data source is the data source for which the relation monitor threshold is defined. The difference can be expressed as absolute value, or as a percentage of the second data source (comparison) value. This difference is compared to a threshold argument with either the greater than or less than operator. The criteria fails when the expression (<absolute or relative difference> <either greater-than or less-than> <threshold>) evaluates to false. The four colon-delimited arguments for a relation monitor are:

  1. The threshold number, optionally preceded by the greater than (>) or less than (<) symbol, and optionally followed by the string "pct". If omitted, greater than is used by default and the expression, difference > threshold, is evaluated.  "<10 pct", ">1000", "50 pct", and "500" are all examples of valid thresholds.
  2. The name of the comparison target. The comparison target must either share the same path with the first target or be fully-qualified. This argument is optional and if omitted the first target is also taken as the comparison target.
  3. The name of the comparison data source, variable, integer or floating point value. In the case of a data source it must belong to the comparison target. This argument is optional and if omitted the monitor threshold data source name is also taken as the comparison data source name. Integer and floating point values can be signed or unsigned. ie: -1.05, 5, 10.1, +5
  4. The temporal offset in seconds to go back in the RRD file that is being fetched from for comparison. Note that a data source value must exist in the RRD file for that exact offset. Choose a multiple of the RRD file step size. This argument is optional and if omitted, it is set to 0.

quotient :

Quotient monitor thresholds are similar to relation monitor thresholds, except that they consider the quotient of two data sources, or alternatively, the same data source at two different time points. For a quotient monitor threshold, Cricket computes the value of the first data source as a percentage of the value second data source (such as 10 is 50% of 20). This percentage is then compared to a threshold argument with either the greater than or less than operator. The criteria fails when the expression (<percentage> <either greater-than or less-than> <threshold>) evaluates to true. The four colon-delimited arguments for a quotient monitor are:

  1. The threshold number, optionally preceded by the greater than (>) or less than (<) symbol followed by the string  "pct". If omitted, greater than is used by default and the expression, difference > threshold, is evaluated.
  2. The name of the comparison target. The comparison target must either share the same path with the first target or be fully-qualified. This argument is optional and if omitted the first target is also taken as the comparison targete.
  3. The name of the comparison data source, variable, integer or floating point value. This data source must belong to the comparison target. This argument is optional and if omitted the monitor threshold data source name is also taken as the comparison data source name. ie: -1.05, 5, 10.1, +5
  4. The temporal offset in seconds to go back in the RRD file that is being fetched from for comparison. Note that a data source value must exist in the RRD file for that exact offset. Choose a multiple of the RRD file step size. This argument is optional and if omitted, it is set to 0.

hunt:

The hunt monitor threshold is designed for the situation where the data source serves as an overflow for another data source; that is, if one data source (the parent) is at or near capacity, then traffic will begin to appear on this (the monitored) data source.  One application of hunt monitor thresholds is to identify premature rollover in a set of modem banks configured to hunt from one to the next.  Specifically, the criteria of the hunt monitor threshold fails if the value of the monitored data source is non-zero and the current value of the parent data source falls below a specified capacity threshold. The three colon-delimited arguments for a hunt monitor are:

  1. The threshold of the parent data source. Generally this should be slightly less than the maximum capacity of the target.
  2. The name of the parent target. The parent target must either share the same path with the monitored target or be fully-qualified. This argument is optional and if omitted the monitored target is also taken as the parent target.
  3. The name of the parent data source. This data source must belong to the parent target. This argument is optional and if omitted the monitor threshold data source name is also take as the comparison data source name.

failures:

The failures monitor threshold is integrated with aberrant behavior detection in RRDtool. This monitor checks the FAILURES RRA for the target and datasource. If the current value is 1, this indicates aberrant behavior. Aberrant behavior detection must be enabled for the target, which requires RRDtool 1.1.x. This threshold may be conditioned on the current value of the datasource. In this case, the threshold is only triggered when both the FAILURES RRA is 1 and the current value of the data source is within a specified range. This range is specified via two colon-delimited arguments; the first is the min or "n" to specify no lower bound and the second is the max or "n" to specify no upper bound.

Alarm Actions

After the monitor threshold is checked for the current value, Cricket may execute one of several actions.  Each action requires one or more arguments, which appear as a colon-delimited list following the action tag in the monitor threshold specification.

SNMP: Generating a SNMP trap is the default action if the action tag is omitted from a monitor threshold specification. To support this default and for backwards compatibility, the action SNMP does not use the action arguments field in the monitor threshold specification. The SNMP action instead requires the attribute trap-address to be set for target. The traps Cricket sends are marked with the enterprise OID ".1.3.6.1.4.1.2595.1.1".  The generic type is 6 and specific type is 4 for failure (violation) of the monitor threshold criteria and 5 for success (recall the trap is cleared on the first success after one or more failures).  There are currently nine varbinds: the monitor type,  the monitor threshold string, the target name, data source name, cricket user name (set to "cricket" on Win32 platforms), instance number (to distinguish targets with multiple instances), instance name, contact name (based on the html dictionary entry contact-name), and data value. These varbinds are set (and could be customized) in the sendMonitorTrap() subroutine in Monitor.pm.

MAIL: This action sends email to a specified address via a Berkeley mailx compatible mail program. The first action argument is the program to invoke to send email. It is assumed that this program is compatible with Berkeley mailx. That is, the program accepts piped input as the message body, and supports a "-s" command flag to specify the subject.  If you don't have such a program on your system, you may wish to customize the code in the sendEmail() subroutine in Monitor.pm to utilize your email program. The second action argument is the recipient's email address. Note that as in the example, you may need to escape special characters. Both arguments are required. The mail message body includes the following information: the monitor type, the monitor threshold string, the target name, data source name, the value of the data source retrieved from the RRD file, and the instance number (to distinguish targets with multiple instances). To change the contents of the message, customize the sendEmail() subroutine in Monitor.pm.

FILE: This action appends and deletes entries (lines) from a file. When the monitor threshold criteria first fails, a line containing details in a space-delimited format is appended to the file specified as the action argument (the FILE action has only one argument). Subsequent failures do not add multiple lines to the file. The FILE action essentially ignores persistent-alarms = true (though some overhead is incurred to detect duplicate lines, so persistent-alarms should be set to false when possible for targets using the FILE action). When the monitor threshold passes again after one or more failures, the line is deleted from the file.  The line details include the target name and the data source name. To include other details, customize the LogToFile() subroutine in Monitor.pm.

EXEC: This action executes a shell command or script. The first action argument is the shell command or script to execute when the monitor threshold criteria fails. The second action argument is the shell command or script to execute when the monitor threshold passes again after one or more failures. The EXEC action provides a mechanism by which automated corrective action can be taken.

FUNC: This action is similar to EXEC, except that a perl subroutine defined in the Cricket scope is executed. The first action argument is the function invoked when the monitor threshold criteria fails. The second action argument is the function invoked when the monitor threshold passes again after one or more failures.  To use this action, you must first modify the entry in the func.pm module to set the global variable gMonFuncEnabled. Using this action requires customization (you must write the subroutines). While this mechanism provides complete flexibility in handling special cases, the invoked subroutines cannot easily accept arguments (this can be done, but the argument list must be included by name in the action arguments which can quickly become unwieldy). If your function requires access to arguments available in the Alarm() and Clear() functions, you might consider adding a new action tag (and sharing your work with the Cricket community).

META: This action is meant to be used to shared threshold monitoring event data with other external systems. This action does nothing. In the sense, that no external action is initiated. There is no mail sent, no SNMP trap generated or any other specific action. What it does is let cricket know the fact that an alarm has been generated or cleared. Cricket stores all active alarms in an internal format call meta files. These files are stored in the cricket-data directory along side each target.rrd file that has monitor-thresholds defined for it. The meta files store alarm data for all Action types.The monitor-threshold line itself and other data is stored in the meta file. Arguments are arbitrary.

Using this action requires customization (you must write the external interface script). The most common uses for this are for sharing event data with event management systems such as NetCool, BigBrother and others. Event management systems often support SNMP, proprietary agents or APIs. This permits a flexible way of interacting with these systems with something other than an SNMP trap.

To provide this, your external script must load the config-tree in memory, query it for active alarms and configured monitoring thresholds and send messages in the appropriate format to the event manager. An example script is provided in the util directory of the Cricket distribution, metaQuery.pl. Note that this is not to be mistaken with real time monitoring, as you have to wait for the collector run to be finished before querying the config-tree or else risk missing a new alarm until the next query.

Monitoring Span

Cricket monitoring thresholds can be extended to look for consecutive threshold failures. The SPAN keyword will require a threshold to be crossed an arbitrary number of consecutive times before triggering an alarm. The keyword SPAN and a span-length value are required to enable this action. At the first threshold verification that passes, the alarm will be cleared. Threshold crosses that have not been promoted to alarms are stored in the meta file associated with the monitored target. Using the following meta file format:

<monitor-threshold> <timestamp-of-first-failure> failure lastval <ds-value-at-time-of-first-failure>

When the time stamp of a threshold cross is older than <span-length> * %rrd-poll-interval%, an alarm is generated. This option is fully compatible with the persistent-alarms option.

 

Questions or comments: contact Jake Brutlag

Michael Bunk | 12 Apr 2006 10:49
Favicon

Re: monitor-thresholds

>     ifInOctets : quotient : 30 pct : : %rrd-max-octets% : MAIL :
> %mail-pgm% : naveen.baldeo\\\ <at> optus.com.au"
>
> This does not do anything. What am I doing wrong.
...
>     ifInOctets : quotient : >80pct : : %rrd-max-octets% : SNMP,
>
> * The second generates an SNMP trap whenever the utilized bandwidth,
> ifInOctets, exceeds 80% of it's maximum capacity, %rrd-max-octets%.
> %rrd-max-octets% is a cricket variable that is replaced at runtime with
> it's real value.
>
>
>
> If this command can generate an SNMP trap, then change the SNMP to MAIL,
> should generate an email.

Double check that %mail-pgm% really exists in the given location and execute 
it manually to make sure that it does not ask stupid questions. Mine asked 
interactively for CC/BCC. Of course Cricket ignored these questions.

Kindest regards,
 Michael

-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language
that extends applications into web and mobile media. Attend the live webcast
and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642
Michael Bunk | 12 Apr 2006 11:03
Favicon

Re: GenRtrConfig 1.5.50 and PIX v7.0

Hi Geoff,

I'm not sure whether I can help you much, but my thought is that Cricket 
always attaches the instance number 0 to you OIDs. Can you make it attach a 
1?

Kindest regards,
 Michael Bunk

On Tuesday 11 April 2006 22:58, Geoffrey Schwartzreich wrote:
> I'm not sure if this specific question has been asked before...a search
> turned up very little.
>
> I'm having an issue with genRtrConfig 1_5_50 and a pair of PIX 515E's that
> I need to monitor for CPU/Temp/Load. I have played around with the targets
> file a bit, and it is trying to get this data, but the following is the
>
> result:
> >Received SNMP response with error code noSuchName. OID:
> >1.3.6.1.4.1.9.9.109.1.1.1.1.4.0
>
> So, I do a snmpwalk -v 1 ip_addr_of_pix 1.3.6.1.4.1.9.9.109.1.1.1.1.4
>
> And I get:
> > SNMPv2-SMI::enterprises.9.9.109.1.1.1.1.4.1 = Gauge32: 4
>
> So, it looks like the OID in the Defaults file is wrong for the PIX v7, but
>
> if I put that OID into the Defaults file I get:
> >Received SNMP response with error code noSuchName. OID:
> >1.3.6.1.4.1.9.9.109.1.1.1.1.4.1.0
>
> Thoughts?
>
> Geoff

-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language
that extends applications into web and mobile media. Attend the live webcast
and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642
Robin Mordasiewicz | 12 Apr 2006 15:34
Favicon

rrdtool 1.2

I have installed rrdtool 1.2 on my system, but I am getting an error in 
the web interface which says
"Current values not available: RRD file version 0003 not supported on this arch."

Is it possible that I can install the older version of rrdtool in say 
/opt/rrdtool-1.0, and then modify cricket to use that rrdtool ?

-------------------------------------------------------
This SF.Net email is sponsored by xPML, a groundbreaking scripting language
that extends applications into web and mobile media. Attend the live webcast
and join the prime developer group breaking into this new coding territory!
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642
Kovács György | 12 Apr 2006 22:24
Picon

Re: rrdtool 1.2


use rrdtool 1.2 
in cricket/lib/RRD/Format.pm find this line

        $self->{'liveHead'} = "L";

and after this line add the following

        $self->{'liveHead3'} = "L L";

if it will not help check the archive, I am sure that there are some relevant posts.

KGy.

2006-04-12, sze keltezéssel 09.34-kor Robin Mordasiewicz ezt írta:
I have installed rrdtool 1.2 on my system, but I am getting an error in the web interface which says "Current values not available: RRD file version 0003 not supported on this arch." Is it possible that I can install the older version of rrdtool in say /opt/rrdtool-1.0, and then modify cricket to use that rrdtool ? ------------------------------------------------------- This SF.Net email is sponsored by xPML, a groundbreaking scripting language that extends applications into web and mobile media. Attend the live webcast and join the prime developer group breaking into this new coding territory! http://sel.as-us.falkag.net/sel?cmd=lnk&kid=110944&bid=241720&dat=121642 _______________________________________________ cricket-users mailing list cricket-users <at> lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/cricket-users